{"created":"2023-06-19T07:56:58.199108+00:00","id":572,"links":{},"metadata":{"_buckets":{"deposit":"de33c9d5-d348-49d3-9f69-6a4b1bcefaad"},"_deposit":{"created_by":14,"id":"572","owners":[14],"pid":{"revision_id":0,"type":"depid","value":"572"},"status":"published"},"_oai":{"id":"oai:kitakyu.repo.nii.ac.jp:00000572","sets":["11:10"]},"author_link":["675","676"],"control_number":"572","item_10006_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"中国浙江省における農村住宅の省エネルギー及び環境改善に関する研究","subitem_alternative_title_language":"ja"}]},"item_10006_date_granted_11":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2017-03-25"}]},"item_10006_degree_grantor_9":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_name":"北九州市立大学"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"27101","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_10006_degree_name_8":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(工学)"}]},"item_10006_description_7":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Rural tourism household was taken as a research subject, and measures were analyzed to improve energy saving and indoor thermal environment of rural residential buildings (including ordinary household and rural tourism household) in three regions in Zhejiang. The study was conducted by a combination of field measurements and simulations. The family and building situation, indoor thermal environment and energy consumption were investigated by field survey. Based on field investigation and measurements, typical buildings were chosen to simulate the indoor thermal environment and energy consumption by improving building envelopes. The results show that indoor thermal environment is poor, especially on top floor; the cooling and heating energy consumption of rural tourism household was higher than ordinary household, especially in summer. The improvement of extrernal wall has the largest single energy saving potential, next is window and airtightness. The building forms, functions and location also have great inference on energy saving.","subitem_description_type":"Abstract"}]},"item_10006_dissertation_number_12":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"甲第105号"}]},"item_10006_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"676","nameIdentifierScheme":"WEKO"}],"names":[{"name":"王, 美燕"}]}]},"item_10006_version_type_18":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"オウ, ビエン","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"675","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-05-12"}],"displaytype":"detail","filename":"(KKDE1105OB)甲第105号_オウビエン.pdf","filesize":[{"value":"16.5 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"(KKDE1105OB)甲第105号_オウビエン","objectType":"fulltext","url":"https://kitakyu.repo.nii.ac.jp/record/572/files/(KKDE1105OB)甲第105号_オウビエン.pdf"},"version_id":"b6838873-dab5-4c90-a83f-17b1de165151"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Rural tourism","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"rural residential building","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"rural tourism household","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"ordinary household","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"energy saving","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"energy consumption structure","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"indoor thermal","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"RESEARCH ON ENERGY SAVING AND ENVIRONMENTAL IMPROVEMENT OF RURAL RESIDENTIAL BUILDINGS IN ZHEJIANG, CHINA","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"RESEARCH ON ENERGY SAVING AND ENVIRONMENTAL IMPROVEMENT OF RURAL RESIDENTIAL BUILDINGS IN ZHEJIANG, CHINA","subitem_title_language":"en"}]},"item_type_id":"10006","owner":"14","path":["10"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2017-05-12"},"publish_date":"2017-05-12","publish_status":"0","recid":"572","relation_version_is_last":true,"title":["RESEARCH ON ENERGY SAVING AND ENVIRONMENTAL IMPROVEMENT OF RURAL RESIDENTIAL BUILDINGS IN ZHEJIANG, CHINA"],"weko_creator_id":"14","weko_shared_id":-1},"updated":"2024-04-10T10:19:40.116744+00:00"}