{"created":"2023-06-19T07:57:06.026126+00:00","id":717,"links":{},"metadata":{"_buckets":{"deposit":"68d91c0a-7a27-4738-97af-f0578fe4e96b"},"_deposit":{"created_by":14,"id":"717","owners":[14],"pid":{"revision_id":0,"type":"depid","value":"717"},"status":"published"},"_oai":{"id":"oai:kitakyu.repo.nii.ac.jp:00000717","sets":["11:10"]},"author_link":["844"],"control_number":"717","item_10006_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"中国東部及び中部における種々の建築パラメータが伝統的住居のエネルギー消費に及ぼす影響に関する研究","subitem_alternative_title_language":"ja"}]},"item_10006_date_granted_11":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2019-09-24"}]},"item_10006_degree_grantor_9":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_name":"北九州市立大学"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"27101","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_10006_degree_name_8":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(工学)"}]},"item_10006_description_7":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The research results indicate that (1) Optimum building azimuth: the three building azimuth intervals with the highest energy saving potentials were observed for S, S-E20 and S-E40 in sequence. (2) Optimum shading depths recommended for each building azimuth interval: the recommended shading depths for S and S-E 20 are 1.37 m and 1.62 m respectively, and those for S-E 40, S-E 60, S-E 80, S-W 20 and S-W 40 are all 2.12 m, as well as those for the other 11 BAs are all 2.37 m. (3) Optimum window-to-wall ratios recommended for each building azimuth interval: the recommended window-to-wall ratios for 18 building azimuth intervals are all 0.2. (4) Optimum wall construction type recommended for each building azimuth interval: the recommended wall construction type for 18 building azimuth intervals are all the vented cavity wall with increased outer layer thickness.","subitem_description_type":"Abstract"}]},"item_10006_dissertation_number_12":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"甲第132号"}]},"item_10006_version_type_18":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"チ, ファンアイ","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"844","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-01-08"}],"displaytype":"detail","filename":"(KKDE1132CF)甲第132号_チ ファンアイ.pdf","filesize":[{"value":"25.0 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"(KKDE1132CF)甲第132号_チ ファンアイ","objectType":"fulltext","url":"https://kitakyu.repo.nii.ac.jp/record/717/files/(KKDE1132CF)甲第132号_チ ファンアイ.pdf"},"version_id":"829c18a7-d357-463c-b2d1-6eb9e6a2c0c8"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Building azimuth","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Shading depth","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Window-to-wall ratio","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"wall construction","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Traditional dwelling","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Energy cost","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Impacts of Various Building Parameters on Energy Consumption of Traditional Dwellings in East and Central China","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Impacts of Various Building Parameters on Energy Consumption of Traditional Dwellings in East and Central China","subitem_title_language":"en"}]},"item_type_id":"10006","owner":"14","path":["10"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2020-01-08"},"publish_date":"2020-01-08","publish_status":"0","recid":"717","relation_version_is_last":true,"title":["Impacts of Various Building Parameters on Energy Consumption of Traditional Dwellings in East and Central China"],"weko_creator_id":"14","weko_shared_id":-1},"updated":"2024-04-03T07:37:33.108365+00:00"}