{"created":"2023-06-19T07:57:18.168315+00:00","id":933,"links":{},"metadata":{"_buckets":{"deposit":"86a2d091-82d5-4cc8-8ca1-ab6a90585b2a"},"_deposit":{"created_by":14,"id":"933","owners":[14],"pid":{"revision_id":0,"type":"depid","value":"933"},"status":"published"},"_oai":{"id":"oai:kitakyu.repo.nii.ac.jp:00000933","sets":["11:10"]},"author_link":["1101"],"control_number":"933","item_10006_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"中国成都の躯体断熱改修による既存住宅の省エネルギー効果と熱環境の改善に関する実証的研究","subitem_alternative_title_language":"ja"}]},"item_10006_date_granted_11":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2021-09-24"}]},"item_10006_degree_grantor_9":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_name":"北九州市立大学"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"27101","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_10006_degree_name_8":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(工学)"}]},"item_10006_description_7":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The indoor thermal environment in the hot summer and cold winter (HSCW) region is the worst in China. Residences in this region are mainly outside-insulated and perform poorly under the intermittent cooling/heating modes in individual rooms. Interior insulation is proposed to be a more suitable way under such usage patterns. Bedrooms of a high-rise residential unit in Chengdu, a typical city in the HSCW region, were retrofitted with interior insulation. Comparative field experiments were performed during the cooling and heating seasons, and the main conclusion can be summarized as follows. Firstly, the retrofitted south bedroom had a good energy-saving effect both in summer and winter. Secondly, the indoor temperature was better controlled in the retrofitted south bedroom, closer to the setpoint. And temperature difference was smaller both horizontally and vertically. Thirdly, the retrofitted south bedroom outperformed the north one in terms of both energy-saving rate and indoor thermal environment.","subitem_description_type":"Abstract"}]},"item_10006_dissertation_number_12":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"甲第173号"}]},"item_10006_version_type_18":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"ヨウ, シン","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"1101","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-12-25"}],"displaytype":"detail","filename":"(KKDE1173YX)甲第173号_ヨウ シン.pdf","filesize":[{"value":"9.5 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"(KKDE1173YX)甲第173号_ヨウ シン","objectType":"fulltext","url":"https://kitakyu.repo.nii.ac.jp/record/933/files/(KKDE1173YX)甲第173号_ヨウ シン.pdf"},"version_id":"398b39fb-aa3b-4c60-a773-b02c88ce2490"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"interior insulation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"intermittent heating/cooling","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"air conditioning load","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"indoor thermal environment","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Empirical Study on Energy Saving and Thermal Environment Improvement of Existing Residential Buildings After Interior Insulation Retrofit in Chengdu, China","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Empirical Study on Energy Saving and Thermal Environment Improvement of Existing Residential Buildings After Interior Insulation Retrofit in Chengdu, China","subitem_title_language":"en"}]},"item_type_id":"10006","owner":"14","path":["10"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2021-12-25"},"publish_date":"2021-12-25","publish_status":"0","recid":"933","relation_version_is_last":true,"title":["Empirical Study on Energy Saving and Thermal Environment Improvement of Existing Residential Buildings After Interior Insulation Retrofit in Chengdu, China"],"weko_creator_id":"14","weko_shared_id":-1},"updated":"2024-03-02T07:48:20.832983+00:00"}