{"created":"2023-06-19T07:57:18.404850+00:00","id":938,"links":{},"metadata":{"_buckets":{"deposit":"cefeba4d-fa4e-4c99-89b4-e918a8a52e4d"},"_deposit":{"created_by":14,"id":"938","owners":[14],"pid":{"revision_id":0,"type":"depid","value":"938"},"status":"published"},"_oai":{"id":"oai:kitakyu.repo.nii.ac.jp:00000938","sets":["11:10"]},"author_link":["1106"],"control_number":"938","item_10006_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"数値流体力学を用いた室内環境と室内湿度分布に関する研究","subitem_alternative_title_language":"ja"}]},"item_10006_date_granted_11":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2021-09-24"}]},"item_10006_degree_grantor_9":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_name":"北九州市立大学"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"27101","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_10006_degree_name_8":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(工学)"}]},"item_10006_description_7":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Due to recent industrial developments and the COVID‐19 pandemic, people are spending more time indoors. Consequently, many researchers have focused on the indoor environment, and indoor air quality is considered more important for human health. Improving indoor air quality depends on effective ventilation and reasonable air distribution. In an air‐conditioned room, the form of airflow organization affects air quality, so air distribution is an important aspect of air‐ conditioning system design. In this study, we used Airpak software by Fluent to perform numerical calculations on the indoor humidity calculation model and study the effects of different ventilation methods on indoor temperature and humidity distribution. The Reynolds averaged Navier–Stokes equation and the RNG (Re‐Normalisation Group) k‐epsilon model were used to predict the airflow pattern in a room, the effects of ventilation on the dew rate, the effects of different ventilation methods, and the effect of indoor wall condensation.","subitem_description_type":"Abstract"}]},"item_10006_dissertation_number_12":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"甲第178号"}]},"item_10006_version_type_18":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"チョウ, ホウエン","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"1106","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-12-25"}],"displaytype":"detail","filename":"(KKDE1178ZF)甲第178号_チョウ ホウエン.pdf","filesize":[{"value":"11.6 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"(KKDE1178ZF)甲第178号_チョウ ホウエン","objectType":"fulltext","url":"https://kitakyu.repo.nii.ac.jp/record/938/files/(KKDE1178ZF)甲第178号_チョウ ホウエン.pdf"},"version_id":"6549a6ae-50aa-4470-9792-d9b4b17973c2"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"indoor air quality","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"humidity","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"ventilation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"CFD (computational fluid dynamics)","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"indoor environment","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Study on Indoor Environment and Indoor Humidity Distribution using Computational Fluid Dynamics","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Study on Indoor Environment and Indoor Humidity Distribution using Computational Fluid Dynamics","subitem_title_language":"en"}]},"item_type_id":"10006","owner":"14","path":["10"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2021-12-25"},"publish_date":"2021-12-25","publish_status":"0","recid":"938","relation_version_is_last":true,"title":["Study on Indoor Environment and Indoor Humidity Distribution using Computational Fluid Dynamics"],"weko_creator_id":"14","weko_shared_id":-1},"updated":"2024-02-27T03:04:29.304549+00:00"}