WEKO3
アイテム
Study on Optimization of Visibility and Energy Efficiency of New "Sudare" for Building Façade
https://kitakyu.repo.nii.ac.jp/records/595
https://kitakyu.repo.nii.ac.jp/records/595a54bd50d-055e-40cd-8945-f103a21ab540
名前 / ファイル | ライセンス | アクション |
---|---|---|
(KKDE1109HA)甲第109号_ハリヤディアーグス (24.6 MB)
|
|
Item type | 学位論文 / Thesis or Dissertation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-11-10 | |||||
タイトル | ||||||
タイトル | Study on Optimization of Visibility and Energy Efficiency of New "Sudare" for Building Façade | |||||
言語 | en | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | SUDARE | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | horizonal shading | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | energy conservation | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | parametric analysis | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | energy efficiency | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | OTTV | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_db06 | |||||
資源タイプ | doctoral thesis | |||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
その他(別言語等)のタイトル | ||||||
その他のタイトル | 建物のファサードに設置される新型「簾」の視認性と省エネルギー効率の最適化に関する研究 | |||||
言語 | ja | |||||
著者 |
ハリヤディ, アーグス
× ハリヤディ, アーグス |
|||||
著者別名 | ||||||
識別子Scheme | WEKO | |||||
識別子 | 702 | |||||
姓名 | Hariyadi, Agus | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Sudare is a traditional Japanese blind made from bamboo. It has long been used in Japanese house, especially in summer. Its original function was to prevent direct solar radiation and introduce natural ventilation. The characteristic Sudare from makes it possible to see through to objects outside the house. As shading device, Sudare can be implemented in hot areas where most of the problem is high cooling energy demand. Recentry, Jakarta has implemented a new standard for new building construction to reduce the energy consumption of office buildings.This has to meet the minimum Overall Thermal Transfer Value (OTTV) of 35 watt/m2. Based on this study, the optimum form of Sudare blind, with a diameter of 10.01 mm and 5 mm spacers. The visibility value of this configuration is 2.65; privacy is 4.27. It also gives better uniformity of daylight distribution, which improves visual performance and comfort. |
|||||
学位名 | ||||||
学位名 | 博士(工学) | |||||
学位授与機関 | ||||||
学位授与機関識別子Scheme | kakenhi | |||||
学位授与機関識別子 | 27101 | |||||
学位授与機関名 | 北九州市立大学 | |||||
学位授与年月日 | ||||||
学位授与年月日 | 2017-09-25 | |||||
学位授与番号 | ||||||
学位授与番号 | 甲第109号 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |