WEKO3
アイテム
Impacts of Various Building Parameters on Energy Consumption of Traditional Dwellings in East and Central China
https://kitakyu.repo.nii.ac.jp/records/717
https://kitakyu.repo.nii.ac.jp/records/7175d78d76e-31b1-4cf8-a063-415662bb712c
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学位論文 / Thesis or Dissertation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-01-08 | |||||
タイトル | ||||||
タイトル | Impacts of Various Building Parameters on Energy Consumption of Traditional Dwellings in East and Central China | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Building azimuth | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Shading depth | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Window-to-wall ratio | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | wall construction | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Traditional dwelling | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Energy cost | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_db06 | |||||
資源タイプ | doctoral thesis | |||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
その他(別言語等)のタイトル | ||||||
その他のタイトル | 中国東部及び中部における種々の建築パラメータが伝統的住居のエネルギー消費に及ぼす影響に関する研究 | |||||
言語 | ja | |||||
著者 |
チ, ファンアイ
× チ, ファンアイ |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The research results indicate that (1) Optimum building azimuth: the three building azimuth intervals with the highest energy saving potentials were observed for S, S-E20 and S-E40 in sequence. (2) Optimum shading depths recommended for each building azimuth interval: the recommended shading depths for S and S-E 20 are 1.37 m and 1.62 m respectively, and those for S-E 40, S-E 60, S-E 80, S-W 20 and S-W 40 are all 2.12 m, as well as those for the other 11 BAs are all 2.37 m. (3) Optimum window-to-wall ratios recommended for each building azimuth interval: the recommended window-to-wall ratios for 18 building azimuth intervals are all 0.2. (4) Optimum wall construction type recommended for each building azimuth interval: the recommended wall construction type for 18 building azimuth intervals are all the vented cavity wall with increased outer layer thickness. | |||||
学位名 | ||||||
学位名 | 博士(工学) | |||||
学位授与機関 | ||||||
学位授与機関識別子Scheme | kakenhi | |||||
学位授与機関識別子 | 27101 | |||||
学位授与機関名 | 北九州市立大学 | |||||
学位授与年月日 | ||||||
学位授与年月日 | 2019-09-24 | |||||
学位授与番号 | ||||||
学位授与番号 | 甲第132号 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |