WEKO3
アイテム
Impacts of Various Building Parameters on Energy Consumption of Traditional Dwellings in East and Central China
https://kitakyu.repo.nii.ac.jp/records/717
https://kitakyu.repo.nii.ac.jp/records/7175d78d76e-31b1-4cf8-a063-415662bb712c
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| Item type | 学位論文 / Thesis or Dissertation(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2020-01-08 | |||||
| タイトル | ||||||
| タイトル | Impacts of Various Building Parameters on Energy Consumption of Traditional Dwellings in East and Central China | |||||
| 言語 | en | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| キーワード | ||||||
| 言語 | en | |||||
| 主題Scheme | Other | |||||
| 主題 | Building azimuth | |||||
| キーワード | ||||||
| 言語 | en | |||||
| 主題Scheme | Other | |||||
| 主題 | Shading depth | |||||
| キーワード | ||||||
| 言語 | en | |||||
| 主題Scheme | Other | |||||
| 主題 | Window-to-wall ratio | |||||
| キーワード | ||||||
| 言語 | en | |||||
| 主題Scheme | Other | |||||
| 主題 | wall construction | |||||
| キーワード | ||||||
| 言語 | en | |||||
| 主題Scheme | Other | |||||
| 主題 | Traditional dwelling | |||||
| キーワード | ||||||
| 言語 | en | |||||
| 主題Scheme | Other | |||||
| 主題 | Energy cost | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_db06 | |||||
| 資源タイプ | doctoral thesis | |||||
| アクセス権 | ||||||
| アクセス権 | open access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
| その他(別言語等)のタイトル | ||||||
| その他のタイトル | 中国東部及び中部における種々の建築パラメータが伝統的住居のエネルギー消費に及ぼす影響に関する研究 | |||||
| 言語 | ja | |||||
| 著者 |
チ, ファンアイ
× チ, ファンアイ |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | The research results indicate that (1) Optimum building azimuth: the three building azimuth intervals with the highest energy saving potentials were observed for S, S-E20 and S-E40 in sequence. (2) Optimum shading depths recommended for each building azimuth interval: the recommended shading depths for S and S-E 20 are 1.37 m and 1.62 m respectively, and those for S-E 40, S-E 60, S-E 80, S-W 20 and S-W 40 are all 2.12 m, as well as those for the other 11 BAs are all 2.37 m. (3) Optimum window-to-wall ratios recommended for each building azimuth interval: the recommended window-to-wall ratios for 18 building azimuth intervals are all 0.2. (4) Optimum wall construction type recommended for each building azimuth interval: the recommended wall construction type for 18 building azimuth intervals are all the vented cavity wall with increased outer layer thickness. | |||||
| 学位名 | ||||||
| 学位名 | 博士(工学) | |||||
| 学位授与機関 | ||||||
| 学位授与機関識別子Scheme | kakenhi | |||||
| 学位授与機関識別子 | 27101 | |||||
| 学位授与機関名 | 北九州市立大学 | |||||
| 学位授与年月日 | ||||||
| 学位授与年月日 | 2019-09-24 | |||||
| 学位授与番号 | ||||||
| 学位授与番号 | 甲第132号 | |||||
| 著者版フラグ | ||||||
| 出版タイプ | VoR | |||||
| 出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||